Tuesday, May 1, 2018

10 GENERAL REQUIREMENTS OF GOOD STAIRS FOR BUILDING

A good stair should provide an easy, quick and safe mode of communication between the various floors of the building. General requirements of good stairs are as mentioned below.

1. LOCATION

It should preferably be located centrally, ensuring sufficient light and ventilation.

2. WIDTH OF STAIR

The width of stairs for public buildings should be 1.8 m and for residential buildings 0.9 m.

3. LENGTH

The flight of the stairs should be restricted to a maximum of 12 and minimum of 3 steps.

4. PITCH OF STAIR

The pitch of long stairs should be made flatter by introducing landing. The slope should not exceed 400 and should not be less than 250.

5. HEAD ROOM

The distance between the tread and soffit of the flight immediately above it, should not be less than 2.1 to 2.3 m. This much of height is maintained so that a tall person can use the stairs with some luggage on its head.

6. MATERIALS

Stairs should be constructed using fire resisting materials. Materials also should have sufficient strength to resist any impact.

7. BALUSTRADE

All open well stairs should be provided with balustrades, to avoid accidents. In case of wide stairs it should be provided with hand rails on both sides.

8. LANDING

The width of the landing should not be less than the width of the stair.

9. WINDERS

These should be avoided and if found necessary, may be provided at lower end of the flight.

10. STEP PROPORTIONS

The ratio of the going and the rise of a step should be well proportioned to ensure a comfortable access to the stair way.
Following empirical rules may be followed.
  • Treads/Goings in cm + 2 (rise in cm) = 60
  • Treads/Goings in cm x (rise in cm) = 400 to 450 appx.
  • Treads/Goings in cm + (rise in cm) = 40 to 45 appx.
  • Standard sizes: Tread 30 cm, Rise 14 cm
Other combinations of rise and going can be calculated by subtracting 20 mm from going and adding 10 mm to rise. Thus other combinations of rise and going would be
  • Rise 15 cm x Tread 28 cm
  • Rise 16 cm x Tread 26 cm
  • Rise 17 cm x Tread 24 cm
Generally adopted sizes of steps are:
  • Public buildings: (27 cm x 15 cm) to (30 x 14 cm)
  • Residential buildings: 25 cm x 16 cm